01 · Drive selection
Sized to the duty, not the nameplate
Heavy-duty overload margin, switching frequency, and the actual cable length are part of the selection — not left to whoever supplies the drive.
VFD-duty motors · 0.55–315 kW · YVF2 / YXVF
A variable-frequency drive changes more than the speed. It changes how the motor is cooled at low speed, what the winding insulation has to survive, where the current goes in the bearings, and which part of the torque curve you are allowed to use. The YVF2 / YXVF series is built for that duty from the frame up.
Bolting a VFD onto a standard YE3 works — for a fan running at 80–100% speed. It stops working when the duty spends real hours at low speed, in a hot plant, on a long cable, or at constant torque. The failure is rarely immediate; it shows up as a winding that smells hot after eighteen months.
| What the drive does | What it breaks on a standard motor | What the VFD motor does instead |
|---|---|---|
| Runs below base speed | The shaft-mounted fan moves almost no air at 30% speed, so the winding cooks at exactly the moment the load is highest | Independent constant-speed cooling fan (IC416) — full airflow at any rotor speed |
| Switches at 4–16 kHz | PWM pulses arrive as a steep wavefront; on a long cable the reflected wave can nearly double the peak voltage at the terminals | Inverter-grade magnet wire and reinforced turn/phase insulation, rated for the pulse stress |
| Creates common-mode voltage | Shaft voltage discharges through the bearings and erodes the raceway | Insulated bearing on the non-drive end and a shaft grounding path on the larger frames |
| Holds constant torque at low speed | Self-ventilation and the standard thermal margin run out; the motor cannot hold the load | Thermal design and fan sized for continuous constant-torque duty across the stated range |
This is why the two products are not interchangeable on paper even when the nameplate kW matches. The frame may be the same; the cooling, insulation system and bearing arrangement are not.
Where they go
Any duty where the flow or the process sets the speed instead of the mains: boiler feed on sliding pressure, mine dewatering on varying inflow, aeration on dissolved-oxygen control, slurry transfer on density, cooling-tower fans on wet-bulb.
Type spectrum
Same IEC frames as the YE series, so the motor still lands on the existing baseplate — but the cooling and insulation system are specified for drive supply, not for the mains.
| Series | Duty | Power | Frame | Poles | Cooling | Typical use |
|---|---|---|---|---|---|---|
| YVF2 | General VFD duty, constant torque below base speed | 0.55–315 kW | 80–355 | 2, 4, 6, 8 | IC416 independent fan | Pumps, fans, conveyors, mixers on a drive |
| YXVF | High-efficiency VFD duty | 0.75–375 kW | 80–355 | 2, 4, 6, 8 | IC416 independent fan | Continuous duties where the kWh bill dominates |
| YBBP | Flameproof VFD duty, Ex d | Quoted per area classification | Per Ex schedule | 2, 4, 6, 8 | IC416 independent fan | Flammable-gas areas: gas boosting, refinery, solvent plants |
Above about 300 kW the cable and switchgear for 380 V become the expensive part of the installation; a high-voltage YKK machine (160–2,500 kW, 6/10 kV) can be supplied for drive duty with the drive and the winding insulation co-specified. Ranges above are supply envelopes, not model commitments — the exact model is fixed against the duty point at quotation.
Duty envelope · indicative
A drive-duty motor is normally sold as constant torque below base speed and constant power above it. What that means for a pump is simple: below base speed you can hold any head the pump can make at that speed; above it you get more flow but the torque falls away.
| Region | Range (typical) | What is available | What to watch |
|---|---|---|---|
| Constant torque | 5–50 Hz | Rated torque continuously, with full cooling from the independent fan | Minimum continuous speed is set by the driven machine, not only by the motor — check pump lubrication and bearing film |
| Constant power | 50–100 Hz | Rated power, torque falls in inverse proportion to speed | Above base speed the mechanical limits of the driven machine matter more than the motor |
| Below minimum | < 5 Hz | Short-term only, or not at all | Low-speed continuous duty needs a different thermal arrangement; ask before assuming |
| Skip bands | Case by case | — | The drive is programmed to jump critical speeds of the train; we need the shaft and baseplate data |
A pump or fan load is quadratic: at 80% speed the shaft power is about half, at 50% speed about one eighth. That is the whole economic case for the drive — the motor only has to survive the trip down there.
We would rather sell the cheaper answer when it is the right one. A general-purpose YE3 or YE4 on a drive is a sensible choice when all of the following hold:
Specify VFD duty when any of these is true:
Send the existing nameplate and the drive model and we will come back with the equivalent YVF2 / YXVF frame, the cooling arrangement, the minimum continuous speed and the torque available at your lowest operating point.
As a package
The failure modes on a VFD-driven train are interface failures: the drive's overload setting against the motor's thermal time constant, the cable against the winding insulation, the minimum speed against the pump's bearing film. Buying them from one place puts that interface on one drawing. The motor can also ship on its own, with or without a drive — a replacement on a palm oil mill's EFB line or screw press is the usual case.
01 · Drive selection
Heavy-duty overload margin, switching frequency, and the actual cable length are part of the selection — not left to whoever supplies the drive.
02 · Cable and filter
Above the drive manufacturer's cable limit we add a dv/dt or sine filter, or specify a reinforced winding. The motor is ordered to match the decision.
03 · Panel
Drive, breaker, line reactor, cooling and terminals assembled and tested as a panel, not shipped as loose components.
04 · Commissioning
Pump, motor, coupling and baseplate aligned; the train run at minimum, base and maximum speed before it leaves.
Compliance
The IE classes in GB 18613-2020 are written for line-start machines. For a motor running from a drive, the meaningful figure is the type-test efficiency at the speed and load where it actually runs, and we state the standard and the test point it was measured against. We do not label a VFD-duty motor with an IE class borrowed from its line-start equivalent. Market certifications — CE, EAC, UL/CSA or a hazardous-area approval — are quoted item by item against the motor, the drive, the voltage and the country of installation.
Minimum speed, maximum speed, load type and cable length decide whether the answer is a standard motor on a drive or a VFD-duty machine. We will tell you which, and why.