Application · mining
Underground sumps to surface, often in stages. The water carries fines, the head is high, and a stopped pump stops the mine.
A multistage centrifugal pump is efficient on clean water at its design point. Underground, neither condition holds: the water carries fines that open wear rings, and the head varies with sump level, so the pump runs off its best efficiency point for much of the day.
The result is a pump that starts at 65% and settles near 45–50%, with impeller and wear-ring replacement every few months. In a three-pump-house arrangement, the maintenance burden multiplies.
Reference: three pump houses at −50, −250 and −500 m on a Chinese coal mine, replacing 24 multistage centrifugal units with six multi-plunger machines. Measured energy saving 22–37% across the three stations.
Typical dewatering duties fall between UDQ 60 and UDZ 600: 60–600 m³/h at 300–3,150 m of head. Where the lift is lower but the flow higher, the V5 slurry pump handles dirty water with solids.
| Duty | Typical value |
|---|---|
| Flow per pump | 100–400 m³/h |
| Discharge pressure | 4–25 MPa |
| Lift per stage | 150–500 m |
| Solids | fine coal / rock fines |
| Efficiency | >90% |
| Wear parts | 5,000 h+ |
Send the existing pump model and a measured power reading — that is enough to size the replacement and estimate the saving.