References & test reports

Measured results from installations in service

Every figure below comes from a site test: flow, pressure, power draw and specific energy measured on the machine, not taken from a catalogue curve.

Installations

Selected projects

Underground pump house
Coal mineDewatering

Three pump houses, −50 / −250 / −500 m

Six reciprocating machines replacing 24 multistage centrifugal pumps: fewer units, lower specific energy, and maintenance carried out on site instead of a factory return.

Shengli oilfield injection station
OilfieldWater injection

Shengli Oilfield — Guanqi & Wanggang stations

Seven-plunger injection pumps running continuously since 2023. Measured specific power down to 0.3 kWh/m³·MPa where the centrifugal units drew 0.5–0.8.

Reference data sheet
Gold mineTwo levels

Gold mine dewatering — 270 m and 51 m levels

Site test reports dated April 2024 for reciprocating pumps on two levels, with the measured duty point and power recorded by the customer's own engineers.

Reference data (PDF) →

Boiler feed pump installation
PowerBoiler feed

Coke dry quenching waste-heat boiler

Feed pump replacement on a CDQ waste-heat boiler: 26.7% energy saving, 128.5 MWh-equivalent saved per year at 8,000 operating hours, 3.2-year payback.

Slurry pump
Non-ferrousSlurry

Non-ferrous mine — slurry transfer

Abrasive slurry above 30% solids by weight, where centrifugal slurry pumps lost efficiency within months of a rebuild.

High pressure piping
IndustrialHigh pressure

Industrial boiler feed — 120 / 130 / 160 t/h

Multistage centrifugal feed pumps replaced by three- and five-plunger units, 19–21% saving at identical steam output.

Documentation

Site test reports

Scanned reports from operating installations. Each shows the pump model, the measured flow and pressure, the electrical input and the resulting specific energy consumption.

Test report 270 m level
Site test report — 270 m levelMine dewatering · April 2024Download PDF →
Test report 51 m level
Site test report — 51 m levelMine dewatering · April 2024Download PDF →
Reference data summary
Reference data summaryTwo levels, before and afterDownload PDF →

Certificates, material reports and factory acceptance test records for a specific order are supplied with the quotation package. Units are built to Chinese reciprocating-pump standards; certification for a target market is quoted item by item.

Want the full reference list?

Tell us the application and we will send the closest comparable installation, with the measured data.

Ask for references