Three pump houses, −50 / −250 / −500 m
Six reciprocating machines replacing 24 multistage centrifugal pumps: fewer units, lower specific energy, and maintenance carried out on site instead of a factory return.
References & test reports
Every figure below comes from a site test: flow, pressure, power draw and specific energy measured on the machine, not taken from a catalogue curve.
Installations
Six reciprocating machines replacing 24 multistage centrifugal pumps: fewer units, lower specific energy, and maintenance carried out on site instead of a factory return.
Seven-plunger injection pumps running continuously since 2023. Measured specific power down to 0.3 kWh/m³·MPa where the centrifugal units drew 0.5–0.8.
Site test reports dated April 2024 for reciprocating pumps on two levels, with the measured duty point and power recorded by the customer's own engineers.
Feed pump replacement on a CDQ waste-heat boiler: 26.7% energy saving, 128.5 MWh-equivalent saved per year at 8,000 operating hours, 3.2-year payback.
Abrasive slurry above 30% solids by weight, where centrifugal slurry pumps lost efficiency within months of a rebuild.
Multistage centrifugal feed pumps replaced by three- and five-plunger units, 19–21% saving at identical steam output.
Documentation
Scanned reports from operating installations. Each shows the pump model, the measured flow and pressure, the electrical input and the resulting specific energy consumption.



Certificates, material reports and factory acceptance test records for a specific order are supplied with the quotation package. Units are built to Chinese reciprocating-pump standards; certification for a target market is quoted item by item.
Tell us the application and we will send the closest comparable installation, with the measured data.