High-speed turbo machinery · oil-free

Truly energy-efficient gas handling solutions

18.5–750 kW centrifugal blowers on magnetic bearings, 15–300 kW air-foil blowers, and air-foil compressors to 500 kPa. No gearbox, no oil, no mechanical contact — 85%+ efficiency where a Roots blower delivers under 65%.

Where the energy goes

Air duty is sized in cubic metres per minute and paid for in kilowatts, continuously. A Roots blower loses its efficiency to tip clearance and to a belt drive; a water-ring vacuum pump spends a third to a half of its shaft power churning sealing water.

A levitated rotor removes both losses. The impeller is the only moving part, it runs at up to 40,000 rpm on a film of magnetic force or air, and nothing touches anything until the rotor lands at standstill.

 Roots vacuum pumpCeramic-bearing turboAir-foil turbo
Rotor speed< 2,000 rpm≤ 20,000 rpm≤ 40,000 rpm
BearingConventional ballCeramic ballHydrodynamic air film
Bearing life1–2 yearsunder 1 yearSemi-permanent
Bearing power loss2–5%2–5%< 0.1%
DriveBeltDirectDirect
Unit efficiency< 65%> 80%> 85%
Noise90–105 dB(A)≤ 90 dB(A)≤ 70 dB(A)
Annual maintenanceBelts, oil, shaft sealsBearing replacementFilter mat

No oil, no water, no gearbox. That removes the oil circuit, the oil cooler, the sealing-water supply and the belt drive from the equipment list — and from the maintenance schedule as well.

At a glance

  • Magnetic-bearing blowers: 18.5–750 kW, pressure rise 60–120 kPa, flow 16.4–640 m³/min
  • Air-foil blowers: 15–300 kW, 40–120 kPa, 14–330 m³/min
  • Air-foil compressors: 75–300 kW, 200–500 kPa, 18–107 m³/min
  • Air-foil vacuum pumps for process duty, to −60 kPa
  • Noise ≤ 70 dB(A) on the air-foil range
  • Built-in surge protection, variable speed, remote monitoring

Field reference

Fushun thermal power — return-air fan retrofit

A magnetic-bearing high-speed blower replaced the return-air fan on a circulating-fluidised-bed boiler. Belt drive and gearbox out, direct-drive rotor in — lower parasitic loss, no lubrication schedule, and stable pressure at part load.

ApplicationCFB return-air fan
MachineMagnetic-bearing blower
StatusIn service

Three families

Magnetic bearings where the power is, air foil where the speed is

Both are oil-free and both are direct drive. Magnetic bearings carry the large rotors and report rotor position continuously; air-foil bearings are the simpler, lower-cost architecture at moderate power.

DHMCB · magnetic bearing

Centrifugal blower

Five-axis active magnetic bearings with digital control. Rotor displacement, vibration and temperature are measured and reported — the machine tells you its condition instead of failing without warning.

  • 18.5–750 kW
  • Pressure rise 60–120 kPa
  • 16.4–640 m³/min

DHK · air foil bearing

Centrifugal blower

Compliant foil bearings riding on an air film generated by the rotor itself. No bearing controller, no electromagnets, no backup-bearing electronics.

  • 15–300 kW
  • Pressure rise 40–120 kPa
  • 14–330 m³/min · ≤ 70 dB(A)

DKY · air foil bearing

Centrifugal compressor

Oil-free compressed air at process pressure, for plants that cannot accept oil carry-over in the air line.

  • 75–300 kW
  • 200–500 kPa
  • 18–107 m³/min

Selection table · magnetic bearing blowers

DHMCB 18–110

Flow in m³/min at 1 atm, 20 °C, 65% RH. Where a cell is blank the model is not offered at that pressure rise.

Model1822303745557590110
Power (kW)18.522303745557590110
60 kPa16.420273442526982105
80 kPa12.71723283443567184
100 kPa———222635485773
120 kPa——————394858

DHMCB 150–750

Model1501852202503004005008001000
Power (kW)150185220250300400500600750
60 kPa140160210228272320420545640
80 kPa109135164175216270325430540
100 kPa96118145146190225270360452
120 kPa7895117123156200240318400

Flow m³/min. Flange sizes from DN125 to DN600 depending on model and pressure rise; dimensions and mass are issued with the datasheet.

Selection tables · air foil bearing

DHK blowers and DKY compressors

DHK blower152237557590110150185220300
Power (kW)152237557590110150185220300
40 kPa16314874100120147201220260330
60 kPa142135537085108141170212278
80 kPa—172842567088110138165220
100 kPa——223546586888110135176
120 kPa——19293748587896114145
DKY compressor7590110150185220300
Power (kW)7590110150185220300
200 kPa253242546678107
300 kPa22283346586996
400 kPa19262941506084
500 kPa18242736455574

Air-foil centrifugal vacuum pumps are built on the same platform; the model is fixed against suction volume and working vacuum, so we quote them from the duty point rather than from a single table.

Monitoring is part of the machine

Every unit can be delivered with a remote monitoring platform: live status, pressure and flow trends, running hours, fault levels and maintenance reminders, presented on a web dashboard and a phone.

  • Device list with online/offline state and location map
  • Real-time curves against historical data
  • Alarm log with fault level, not just a trip signal
  • Maintenance schedule driven by actual running hours
  • Role-based access for the plant, the service team and the distributor

Where they are used

  • Wastewater aeration. Continuous duty, wide turndown, and the electricity bill is the largest line in the plant budget.
  • Power plant FGD oxidation air and CFB return air. Constant pressure, long runs, no tolerance for a gearbox failure.
  • Coal-mine gas drainage and ventilation. High suction volume at moderate vacuum, flow chasing methane concentration all shift.
  • Paper, chemical and pharmaceutical vacuum. Dry running where the process cannot take oil or water carry-over.
  • Cement, steel and glass. Process air and combustion air at stable pressure.

Certification for a specific market — CE, ATEX, EAC, or a mining approval such as MA — is quoted item by item against the target country and application. We do not describe a machine as certified for a market where that approval has not been issued for the delivered configuration.

Application · biogas

Biogas: extraction at the pond, pressure at the engine

Palm oil mill effluent (POME), landfill, starch and livestock waste. The gas leaves the digester at atmospheric pressure, saturated with water and carrying H2S, and every plant has to move it twice — once out of the covered lagoon, once into the engine.

DutyPressure bandMachineWhat it is doing
Covered lagoon and gas-well extraction−5 to −30 kPaMagnetic-bearing vacuum pumpHolding the cover under negative pressure so the gas goes to the flare or the engine instead of leaking at the pond edge
Boosting to genset, boiler or flare10 to 80 kPaDHMCB magnetic-bearing blowerGas production moves through the day; variable speed follows it instead of throttling a valve
First stage ahead of upgrading200 to 500 kPaMagnetic-bearing or geared multistage compressorFeed pressure for membrane, PSA or amine wash, quoted on the duty point. Ceramic ball bearings are not used in this band. Cylinder filling at 250 bar is a different machine and not ours
Aerobic polishing of POME, composting40 to 80 kPaDHK air-foil or DHMCB blowerAir duty, not gas duty — continuous aeration, the same as a municipal wastewater plant

Bearing choice on gas duty

No air-foil bearings on biogas

An air-foil bearing rides on a gas film that only exists above a minimum speed. Every start and stop is a rub between foil and shaft, and in a flammable atmosphere that rub is a spark and static risk. On gas duty we specify the magnetic-bearing machine — no contact at any speed, start-up included — or, for blowers and vacuum pumps, the ceramic-ball-bearing version, whose rolling elements are non-metallic and do not spark. Air-foil stays where the medium is air: aeration, process air, combustion air.

Compression to 200–500 kPa is a different case: at those pressure ratios and speeds a ceramic ball bearing set is not specified, so that stage is geared multistage or magnetic bearing. We select between the two against the duty point, not by habit.

Why a contact-free rotor suits a gas plant

  • Nothing in the gas path to poison the downstream. No oil mist reaching the desulphuriser or the membrane.
  • 8,000 hours a year. A digester does not take weekends. With a levitated rotor the maintenance items are bearings and filters, not a gearbox rebuild.
  • Typical turndown 45 to 100% of design flow. Gas yield drops after a wet season or when the mill runs light; the machine turns down instead of blowing off.
  • No shaft seal. Nothing to repack on a schedule, and one less leak path on a gas line.

The part that is not off the shelf

Biogas is flammable — methane's lower explosive limit is 5% by volume — and it arrives wet and sour. The machine, motor, terminal box and instruments are built to the hazardous-area classification of the site; the gas path is gas-tight, the bearing cavity is separated by buffer air, and the train needs leak detection, flame arrestor and venting. That configuration is quoted machine by machine, with the approval applied for against the country it will be sold into — ATEX Zone 1 or 2, IECEx, or the local equivalent.

Where the approval has not been issued for the configuration we would deliver, we say so, and propose an Ex-rated Roots or liquid-ring set for that duty rather than quote an approval we do not hold.

To quote a biogas machine

Six numbers and we can size it

Gas flowm³/h — normal or actual, please say which
Methane content% vol, and CO2 if known
H2Sppm before and after desulphurisation
Pressure bandsuction and discharge, kPa
Running hoursper year, and whether the gas flow is steady
Site classificationhazardous zone, ambient temperature, altitude

Malaysia and Indonesia: the usual starting points are covered-lagoon POME plants, palm oil mill captive power and landfill sites. We supply the gas-handling machines and work with local partners for survey, installation and service.

OEM & private label

Supplied under your brand, if that is what you need

Every machine on this page can be built to order under the nameplate of a distributor, integrator or project contractor: documentation, packing, paint scheme and label set to your specification. Certification, where a market requires it, is applied for against the brand and the market it will be sold in — we do not pass off one market's approval as another's.

Replace the Roots blower, keep the pipework.

Send the nameplate of the machine you are running now. We answer with the equivalent levitated model, its power at your duty, and the annual kWh difference.

Ask for a comparison