Application · biogas
Biogas: extraction at the pond, pressure at the engine
Palm oil mill effluent (POME), landfill, starch and livestock waste. The gas leaves the digester at atmospheric pressure, saturated with water and carrying H2S, and every plant has to move it twice — once out of the covered lagoon, once into the engine.
| Duty | Pressure band | Machine | What it is doing |
| Covered lagoon and gas-well extraction | −5 to −30 kPa | Magnetic-bearing vacuum pump | Holding the cover under negative pressure so the gas goes to the flare or the engine instead of leaking at the pond edge |
| Boosting to genset, boiler or flare | 10 to 80 kPa | DHMCB magnetic-bearing blower | Gas production moves through the day; variable speed follows it instead of throttling a valve |
| First stage ahead of upgrading | 200 to 500 kPa | Magnetic-bearing or geared multistage compressor | Feed pressure for membrane, PSA or amine wash, quoted on the duty point. Ceramic ball bearings are not used in this band. Cylinder filling at 250 bar is a different machine and not ours |
| Aerobic polishing of POME, composting | 40 to 80 kPa | DHK air-foil or DHMCB blower | Air duty, not gas duty — continuous aeration, the same as a municipal wastewater plant |
Bearing choice on gas duty
No air-foil bearings on biogas
An air-foil bearing rides on a gas film that only exists above a minimum speed. Every start and stop is a rub between foil and shaft, and in a flammable atmosphere that rub is a spark and static risk. On gas duty we specify the magnetic-bearing machine — no contact at any speed, start-up included — or, for blowers and vacuum pumps, the ceramic-ball-bearing version, whose rolling elements are non-metallic and do not spark. Air-foil stays where the medium is air: aeration, process air, combustion air.
Compression to 200–500 kPa is a different case: at those pressure ratios and speeds a ceramic ball bearing set is not specified, so that stage is geared multistage or magnetic bearing. We select between the two against the duty point, not by habit.
Why a contact-free rotor suits a gas plant
- Nothing in the gas path to poison the downstream. No oil mist reaching the desulphuriser or the membrane.
- 8,000 hours a year. A digester does not take weekends. With a levitated rotor the maintenance items are bearings and filters, not a gearbox rebuild.
- Typical turndown 45 to 100% of design flow. Gas yield drops after a wet season or when the mill runs light; the machine turns down instead of blowing off.
- No shaft seal. Nothing to repack on a schedule, and one less leak path on a gas line.
The part that is not off the shelf
Biogas is flammable — methane's lower explosive limit is 5% by volume — and it arrives wet and sour. The machine, motor, terminal box and instruments are built to the hazardous-area classification of the site; the gas path is gas-tight, the bearing cavity is separated by buffer air, and the train needs leak detection, flame arrestor and venting. That configuration is quoted machine by machine, with the approval applied for against the country it will be sold into — ATEX Zone 1 or 2, IECEx, or the local equivalent.
Where the approval has not been issued for the configuration we would deliver, we say so, and propose an Ex-rated Roots or liquid-ring set for that duty rather than quote an approval we do not hold.
To quote a biogas machine
Six numbers and we can size it
Gas flowm³/h — normal or actual, please say which
Methane content% vol, and CO2 if known
H2Sppm before and after desulphurisation
Pressure bandsuction and discharge, kPa
Running hoursper year, and whether the gas flow is steady
Site classificationhazardous zone, ambient temperature, altitude
Malaysia and Indonesia: the usual starting points are covered-lagoon POME plants, palm oil mill captive power and landfill sites. We supply the gas-handling machines and work with local partners for survey, installation and service.