中文 电脑版

Application · mining

Mine dewatering pumps for high head and abrasive water

Underground sumps to surface, often in stages. The water carries fines, the head is high, and a stopped pump stops the mine.

What goes wrong with centrifugal dewatering pumps

A multistage centrifugal pump is efficient on clean water at its design point. Underground, neither condition holds: the water carries fines that open wear rings, and the head varies with sump level, so the pump runs off its best efficiency point for much of the day.

The result is a pump that starts at 65% and settles near 45–50%, with impeller and wear-ring replacement every few months. In a three-pump-house arrangement, the maintenance burden multiplies.

How we specify it

Reference: three pump houses at −50, −250 and −500 m on a Chinese coal mine, replacing 24 multistage centrifugal units with six multi-plunger machines. Measured energy saving 22–37% across the three stations.

Selection range

Typical dewatering duties fall between UDQ 60 and UDZ 600: 60–600 m³/h at 300–3,150 m of head. Where the lift is lower but the flow higher, the V5 slurry pump handles dirty water with solids.

← 左右滑动查看完整表格 / swipe to see all columns
DutyTypical value
Flow per pump100–400 m³/h
Discharge pressure4–25 MPa
Lift per stage150–500 m
Solidsfine coal / rock fines
Efficiency>90%
Wear parts5,000 h+

What we need to quote

Replacing an existing dewatering station?

Send the existing pump model and a measured power reading — that is enough to size the replacement and estimate the saving.

Send details
Multi-plunger pumpsSlurry pumpsMaglev blowersMobile pump unitsMotors IE3–IE5VFD motorsIndustrial AI box

大连宏实科技有限公司 · DALIAN HONGSHI TECHNOLOGY

Related sites Fluid machinery energy-saving calculator·KSTS — biogas & bioenergy, Sabah

jeeftang@hschina.com

© 2026 · Mobile edition · 手机版

⌂Home ✉Get a quote