Engineering tools

Pump sizing & energy saving calculator

Two calculations we run on every project: what a duty point costs in shaft power, and what changes when a centrifugal pump is replaced by a plunger pump. Everything runs in your browser — no data is sent anywhere.

Volume flow at duty point
Discharge head minus suction head, including pipe losses. Pressure × 102 ≈ head in m (10 MPa ≈ 1,019 m for water)
90% is the published figure for the TL range
Wire-to-water efficiency = hydraulic power ÷ measured input power. 45–68% is common for a worn multistage unit
Motor and transmission losses on the new unit — used to convert shaft power to grid input
Ticked: motor = selection-point shaft power × 1.10. Unticked: duty-point shaft power × 1.10
Use one currency throughout: e.g. 0.08 in USD or 0.64 in CNY
Optional — used only for simple payback

Results

Hydraulic power—
New pump shaft power—
New pump grid input—
Existing pump grid input—
New pump energy—
New pump energy cost—
Annual saving—
Simple payback—
CO₂ avoided—
Recommended motor—

Phyd = ρ · g · Q · H / 3.6×10⁶ [kW, Q in m³/h]  ·  Pshaft = Phyd / η  ·  CO₂ factor 0.581 kg/kWh
Pulp density as a mass fraction
2.7 for typical rock / coal tailings

Results

Mixture density—
Mixture specific gravity—
Hydraulic power—
Shaft power—
Annual energy—
Annual energy cost—

ρmix = 1 / (c/ρs + (1−c)/ρw)  ·  c = solids mass fraction  ·  Pshaft = ρmix·g·Q·H / (3.6×10⁶ · η)

How to read the result

These are screening numbers, not a selection. They assume clean-fluid power with the efficiency you enter, and they ignore NPSH, viscosity correction and motor margin. A real selection adds a model-rating margin (+10% flow, +1 MPa) and then sizes the motor at ×1.10 of that shaft power — the same chain we use in our proposal system. The calculator shows both the duty point and the selection point.

What usually surprises people

The shaft power of a worn centrifugal pump is often 1.6–2× the new pump — not because the motor is oversized, but because efficiency has fallen away from the design point. Measured input power is the single most useful number you can give us.

Payback assumptions

Simple payback only. It ignores maintenance savings (typically 30–50% of the energy saving on abrasive duties), downtime and the residual value of the old unit — so the real payback is usually shorter than shown.